Thermocouple with exchangeable measuring insert, only for combination with already built-in protection tubes on measuring place (otherwise no insulation between process-connection and interior connection head), for middle and high operating pressures Attention: with directly built-in (without additional protective tube) can become the measuring insert in the
extension tube soldered or welded (insulation between process-connection and interior connection head, measuring insert not replaceable) - with order declares!
Construction
Basic implementation
explosion-proof (build in protective tube necessary)
Connection head
Form B according DIN 43 729
Form BUZ for explosion-proof design according DIN 43 729
on inquiry
Protection classification
IP 54 according DIN 60529
on inquiry
Application temperature
up to +800°C
Thermo junction
J (Fe-CuNi) DIN EN 60584
K (NiCr-Ni) DIN EN 60584
on inquiry
Number of Thermo junction
1 thermocouple
2 thermocouples
Wire size
1 mm
Protective tube material
1.4571
on inquiry
Measuring insert diameter d1/ Extension tube diameter d2
6/9
6/11
8/12
on inquiry
Insert length L1
on inquiry
extension tube length L2
130 mm
on inquiry
process connection
outside thread
cup nut
Thread
M18x1,5
M20x1,5
M27x2
G1/2
G3/4