Thermocouple with exchangeable shealted measuring insert and protective tube for welding in
Construction
Basic implementation
EX-implementation
Connection head
Form B according DIN 43 729
Form BUZ for explosion-proof design according DIN 43 729
on inquiry
Protection classification
IP 54 according DIN 60529
on inquiry
Application temperature
up to +800°C
Thermo junction
J (Fe-CuNi) DIN EN 60584
K (NiCr-Ni) DIN EN 60584
on inquiry
Number of Thermo junction
1 thermocouple
2 thermocouples
Protective tube material
1.0460 (C22.8)
1.4571
on inquiry
Protective tube Form 4 for welding in
according DIN 43 772
Form; L1; L3; ød1; ød2; measuring insert-ø; thread
D1; 140; 65; 24; 12,5; 6; M18x1,5
D2; 200; 125; 24; 12,5; 6; M18x1,5
D4; 200; 65; 24; 12,5; 6; M18x1,5
D4S*; 140; 65; 18; 9; 3; M14x1,5
D5; 260; 125; 24; 12,5; 6; M18x1,5
on inquiry
extension tube length L2
130 mm
on inquiry