With connection head
Special stainless steel sheated thermocouples
Thermocouples for shipbuilding applications (GL)
Thermocouple with explosion proof
Measuring inserts
Special types
Precision thermocouples
Cable sensors
| product | representation | sensor* | thermowell material | application temperature | process connection |
210 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 on inquiry |
1.4749 1.4762 on inquiry 1.4841 |
up to +1000°C |
without, stop flange 22 or adjustable thread joint |
220 |
![]() |
K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
adjustable thread joint M18x1,5; M20x1,5; G1/2A; G3/4A |
221 |
![]() |
K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
additional protective tube with adjustable thread joint 18x1,5; M20x1,5; G1/2A; G3/4A |
230 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
Lock nut M27x2 |
231 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
without, Stop flange 15 oder adjustable thread joint |
240 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
without, Stop flange 15 or adjustable thread joint |
244 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 on inquiry |
1.4749 1.4762 on inquiry 1.4841 |
up to +1000°C |
without, stop flange 22 or adjustable thread joint |
245A |
![]() |
B (PtRh30-PtRh6) DIN EN 60584 J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 on inquiry |
C 610 C 799 on inquiry |
up to +1600°C |
without or stop flange 32 |
247A |
![]() |
B (PtRh30-PtRh6) DIN EN 60584 J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 on inquiry |
C 610 C 799 on inquiry |
up to +1600°C |
without, stop flange 22 or adjustable thread joint |
247B |
![]() |
B (PtRh30-PtRh6) DIN EN 60584 J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 on inquiry |
C 610 C 799 on inquiry |
up to +1600°C |
without, Stop flange 15 oder adjustable thread joint |
248 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
Lock nut or srewing neck M20x1,5; G1/2; M18x1,5; M27x2; G3/4 |
254 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 |
up to +800°C |
fix threaded joint M20x1,5; G1/2A; M27x2; G3/4A |
257 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.0460 (C22.8) 1.4571 on inquiry |
up to +800°C |
for welding in |
258 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
fix threaded joint M20x1,5; G1/2A; M20x2; G3/4A |
259 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
fix threaded joint M20x1,5; G1/2A |
260 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
on inquiry up to +800°C |
for laboratory work or for built-in fittings |
261 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
on inquiry up to +800°C |
for laboratory purposes |
270 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 1.4841 on inquiry |
-200 to +1000°C |
fix threaded joint M20x1,5; G1/2A |
272 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
fix threaded joint |
273 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 1.4841 2.4816 on inquiry |
-200 to +1000°C |
without; solderable or adjustable thread joint |
280 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 1.4841 on inquiry |
-200 to +1000°C |
fix threaded joint M20x1,5; G1/2A |
282 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 1.4841 2.4816 on inquiry |
-200 to +1000°C |
without; solderable or adjustable thread joint; connector on inquiry |
285 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 1.4841 2.4816 on inquiry |
-200 to +1000°C |
without (insertation in enclosure of protection or for laboratory use); solderable or adjustable thread joint |
288 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 1.4841 2.4816 on inquiry |
-200 to +1000°C |
universal application (e.g. for laboratory use); solderable or adjustable thread joint |
290 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 on inquiry |
up to +800°C |
adjustable thread joint M18x1,5 |
294 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4541 1.4571 1.4841 2.4816 on inquiry |
-200 to +1000°C |
without; solderable or adjustable thread joint |
500 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
up to +800°C |
stainless steel ring |
506 |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
to +200°C (max. 85°C on transmitter) |
for laboratory purposes |
511 |
![]() |
B (PtRh30-PtRh6) DIN EN 60584 J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 on inquiry |
1.4571 |
whole definition range of thermocouple |
Thread e. g. G1/2A |
PTE |
![]() |
B (PtRh30-PtRh6) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 R (PtRh13-Pt) DIN EN 60584 Au-Pt DIN EN 62460 Pt-Pd DIN EN 62460 |
C 799 |
without |
|
SKTE |
![]() |
S (PtRh10-Pt) DIN EN 60584 on inquiry |
C 799 |
applicable to max. 200 K above particular fixing point temperature |
Precision thermocouple with miniature fixed-point cell |
SKTE-F |
![]() |
on inquiry N (NiCrSi-NiAl) DIN EN 60584 |
1.4571 on inquiry |
Precision thermocouple with miniature fixed-point cell |
|
FP-MTE |
![]() |
B (PtRh30-PtRh6) DIN EN 60584 L (Fe-CuNi) DIN 43 710 J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 on inquiry N (NiCrSi-NiAl) DIN EN 60584 |
1.4541 1.4571 1.4841 2.4816 |
Sheathed thermocouple with fixed-point cell |
|
K1T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 |
on inquiry, dependent on sensor and protective tube material |
without |
K2T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
without |
K3T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry 1.4841 2.4816 |
on inquiry, dependent on sensor and protective tube material |
without |
K4T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
on inquiry stainless steel |
on inquiry, dependent on sensor and protective tube material |
Thread such as M8 for srewing in |
K5T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
fix threaded joint such as G3/4A |
K6T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
adjustable threaded joint such as M10x1 |
K7T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
adjustable threaded joint such as M10x1 |
K8T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
1.4571 on inquiry |
on inquiry, dependent on sensor and protective tube material |
lock nut such as G1/2 |
K9T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
on inquiry 1.4305 |
on inquiry, dependent on sensor and protective tube material |
bajonet lock cap, suitable threaded nipple available |
K10T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
on inquiry stainless steel brass aluminium |
on inquiry, dependent on sensor and protective tube material |
without or drilling for screw M4 in protective case |
K11T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
on inquiry stainless steel brass |
on inquiry, dependent on sensor and protective tube material |
Clamping band with clamping rang 10 ... 190 mm ( >100 mm clamping band enclosed) |
K12T |
![]() |
J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 on inquiry |
on inquiry stainless steel |
on inquiry, dependent on sensor and protective tube material |
without |
FP-KTE |
![]() |
B (PtRh30-PtRh6) DIN EN 60584 L (Fe-CuNi) DIN 43 710 J (Fe-CuNi) DIN EN 60584 K (NiCr-Ni) DIN EN 60584 S (PtRh10-Pt) DIN EN 60584 N (NiCrSi-NiAl) DIN EN 60584 |
1.4571 on inquiry |
Thermocouple cable probe with fixed-point cell |



210