Home > Product cataloque > Resistance thermometers > Resistance thermometers
product summary Resistance thermometers
 
 
product representationsensor*thermowell materialapplication temperatureprocess connection
308 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

1 x Pt 500 Class B

1 x Pt 1000 Class B

on inquiry

 

-40°C to +85°C

holes for wall mounting

320 

1 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

1 x Pt 500 Class B

1 x Pt 1000 Class B

on inquiry

1.4571

on inquiry

-35 °C to +100 °C

Penetration resistance thermometer

325 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

up to +380°C for GL-Design

-200 to +600°C

without; adjustable thread joint M20x1,5, G1/2A, M27x2, G3/4A; combination protective tube M27x2, G3/4A

340 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

up to +380°C for GL-Design

-50 to +400°C

on inquiry

-200 to +600°C

without, Stop flange 15 oder adjustable thread joint

342 

1 x Pt 100 Class B DIN EN 60751

1.4571

brass

0 °C to 60 °C

0 °C to 120 °C

0 °C to 200 °C

Combination of resistance and glass thermometer

348 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-50 to +400°C

on inquiry

-200 to +600°C

cap nut or screw-in sleeve M20x1,5; G1/2; M18x1,5; M27x2; G3/4

350 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-40 °C to +90 °C

Room resistance thermometer inside a plastic case

351 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

1 x Pt 500 Class B

1 x Pt 1000 Class B

on inquiry

1.4571

on inquiry

-40 °C to +120 °C

Room resistance thermometer inside a metal case

352WZ 

1 x Pt 100 1/3 Class B according DIN EN 60751

1 x Pt 100 Class B according DIN EN 60751 (with sub classes)

1.4571

0 °C to 200 °C

0 °C to 140 °C

Resistance heatmeter

354 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

up to +380°C for GL-Design

-50 to +400°C

on inquiry

-200 to +600°C

fix threaded joint M20x1,5; G1/2A; M27x2; G3/4A

357 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.0460 (C22.8)

1.4571

on inquiry

up to +380°C for GL-Design

-50 to +400°C

on inquiry

-200 to +600°C

for welding in

358 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

up to +380°C for GL-Design

-200 to +600°C

fix threaded joint M20x1,5; G1/2A; M27x2; G3/4A

359 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

up to +380°C for GL-Design

-200 to +600°C

fix threaded joint M20x1,5; G1/2A

360 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-50 to +400°C

on inquiry

-200 to +600°C

for laboratory work or for built-in fittings

361 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

-50 to +400°C

on inquiry

-200 to +600°C

for laboratory purposes

361WZ 

1 x Pt 100 1/3 Class B according DIN EN 60751

1 x Pt 100 Class B according DIN EN 60751 (with sub classes)

1.4571

0 °C to 200 °C

0 °C to 140 °C

for laboratory purposes

 

370 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-50 to +400°C

on inquiry

-200 to +600°C

for laboratory purposes or or built-in protective fittings

371 

1 x Pt 100 Class B DIN EN 60751

1 x Pt 500 Class B

1 x Pt 1000 Class B

on inquiry

1 x Ni 100 Class B DIN 43760

1 x Ni 500 Class B DIN 43760

1 x Ni 1000 Class B DIN 43760

Cu tube blank

Cu tube with heat shrink hose covered ( only up to 140°C)

for Pt: -40 °C to +140 °C

for Pt: -40 °C to +350 °C

for Ni: -40 °C to + 140 °C

for Ni: - 40 °C to + 250 °C

without

372 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

up to +380°C for GL-Design

-50 to +400°C

on inquiry

-200 to +600°C

fix threaded joint M20x1,5; G1/2A

373 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-50 to +400°C

on inquiry

-200 to +600°C

fix threaded joint M20x1,5; G1/2A

374 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-50 to +400°C

on inquiry

-200 to +600°C

flange welded on protective tube d1, d2 and b according DIN or on inquire

380 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-50 up to +300°C

-200 up to +300°C

fix threaded joint M18x1,5; M20x1,5; G1/2A

388 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

-50 to +400°C

on inquiry

-200 to +600°C

without

400WZ 

1 x Pt 100 1/3 Class B according DIN EN 60751

1 x Pt 100 Class B according DIN EN 60751 (with sub classes)

1.4571

0 °C to 140 °C

Resistance heatmeter

405 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry

-50 up to +400°C (max. 120°C near the connector)

fix threaded joint G1/2A

406 

1 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry

-50 up to +400°C (max. 85°C near the transmitter)

solid threaded joint G1/2A

407 

1 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry

-50 up to +400°C (max. 85°C near the transmitter)

solid threaded joint G1/2A

408 

1 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry

-50 up to +400°C (max. 85°C near the transmitter)

solid threaded joint G1/2A

409 

1 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry

-50 up to +400°C (max. 85°C near the transmitter)

Small resistance thermometer for screwing in

411 

1 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

1 x Pt 1000 Class B

1.4571

on inquiry

-50 to +400°C

-200 to +600°C

Thread

412 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry

-50 up to +400°C (max. 85°C near the connector)

Small resistance thermometer for screwing in with connector M12x1

443 

HL-sensor

 

-30 °C to +80 °C

holes for wall mounting;
output 4...20mA

444 

HL-sensor

 

-30 °C to +80 °C

holes for wall mounting;
output 0...10V

Pt100 

Pt100

1.4571

stainless steel

 

Precision resistance thermometer

Pt100h 

Pt100

1.4571

stainless steel

 

Precision resistance thermometer for high temperature

K1W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

without

K4W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

on inquiry

stainless steel

on inquiry, dependent on sensor and protective tube material

Thread such as M8 for srewing in

K5W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

fix threaded joint such as G3/4A

K6W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

adjustable threaded joint such as M10x1

K7W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

adjustable threaded joint such as M10x1

K8W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

1.4571

on inquiry

on inquiry, dependent on sensor and protective tube material

lock nut such as G1/2

K9W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

on inquiry

1.4305

on inquiry, dependent on sensor and protective tube material

bajonet lock cap, suitable threaded nipple available

K10W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

on inquiry

stainless steel

brass

aluminium

on inquiry, dependent on sensor and protective tube material

without or drilling for screw M4 in protective case

K11W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

on inquiry

stainless steel

brass

on inquiry, dependent on sensor and protective tube material

Clamping band with clamping rang 10 ... 190 mm ( >100 mm clamping band enclosed)

K12W 

1 x Pt 100 Class A DIN EN 60751

2 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

2 x Pt 100 Class B DIN EN 60751

on inquiry

on inquiry

stainless steel

on inquiry, dependent on sensor and protective tube material

without

K13 

1 x Pt 100 Class A DIN EN 60751

1 x Pt 100 Class B DIN EN 60751

on inquiry

   

without