Menu
Inquiry about the product Model series 340
Model series 340

Measuring the temperature in pipelines or containers;

implementations with flange or with adjustable thread joint

are available (parts and accessories)

Protection classification

IP 54 according DIN 60529

on inquiry

Application temperature

-200 to +600°C

-50 to +400°C

on inquiry

Temperature sensor

1xPt 100 cl. F0,15 or W0,15 acc. to DIN EN 60751

1xPt 100 cl. F0,3 or W0,3 acc. to DIN EN 60751

2xPt 100 cl. F0,3 or W0,3 acc. to DIN EN 60751

2xPt 100 cl. F0,15 or W0,15 acc. to DIN EN 60751

on inquiry

Circuitry

2 wire circuit

3 wire circuit

4 wire circuit

Protective tube diameter d

on inquiry

15 mm

Nominal length L

on inquiry

Protective tube material

1.4571

on inquiry

Construction

Basic implementation

Ex-implementation (intrinsically safe)

Connection head

Form B according DIN 43 729

Form B (Form BUZ for explosion-proof design) according DIN 43 729

on inquiry